When a person suffers cardiac arrest, there is a one in five chance a potentially life-saving Automated External Defibrillator (AED) is nearby. But up to 30 per cent of the time, the device is locked inside a closed building, according to a study led by 勛圖惇蹋 Engineering researchers, published August 15 in the .
The work was conducted by Professor Timothy Chan of the Department of Mechanical & Industrial Engineering at the University of Toronto, in collaboration with , led by Dr. Laurie Morrison at Li Ka Shing Institute of St Michael's Hospital in Toronto.
Currently, AED placement in Canada does not necessarily consider accessibility of the device during an emergency. Many AEDs are located within office buildings, schools and recreation facilities, which tend to be open for a limited set of hours during the daytime.
Toronto had 2,440 cases of out-of-hospital cardiac arrests in a public place during the study period, and 767 AED locations. Of these AED locations, 73.5 per cent were not open 24-hours a day, and 28.6 per cent were closed on weekends. Of the total number of out-of-hospital cardiac arrests, 451 were located near an AED but only 354 were located near an AED when the AED was accessible, resulting in a coverage loss of 21.5 per cent.
When researchers looked at cardiac arrests during evenings, nights and weekends, which is when the majority of all out-of-hospital cardiac arrests occur, coverage diminished to 31.6 percent.
The researchers concluded that a significant proportion of out-of-hospital cardiac arrests occur close to a public AED that is inaccessible at the time of the arrest, and a model that accounts for both location and availability when determining AED placement has the potential to significantly increase the likelihood of accessing an AED when needed.
Our research has shown AED availability for cardiac arrests is overestimated when time factors, such as building access and time of day, are not considered, said Chan (right). The model considers time of day, building access and location information to optimize AED availability. Using the model, we found an average 25 per cent improvement in AED accessibility for cardiac arrests at all times of day.
Government legislation mandating all AEDs be registered with emergency medical services dispatch centers and accessible to the public 24/7 would also improve access to AEDs.
But coverage is only one issue, according to the studys authors: AED coverage does not necessarily equal survival, because the existence of an AED still doesnt necessarily mean the AEDs are being used.
Accessibility is only one piece of the larger puzzle in optimizing public defibrillator use and bystander response in an emergency, said Chan, who is also director of the Centre for Healthcare Engineering at 勛圖惇蹋.
In an accompanying editorial comment, Robert J. Myerburg, a professor of medicine at the University of Miami Miller School of Medicine, said the study is important and should be included in planning strategies for AED locations, but society would benefit more by both achieving better outcomes after out-of-hospital cardiac arrest and reducing the number that occur in the first place.
Now we need a parallel effort to develop a roadmap for improving prediction and prevention of out-of-hospital cardiac arrest, he said.